HPLC Column, RP PFP, 3um, 4.6mm ID x 250mm Length, 100A. Cogent Brand. 1 EA.
Additional Info:
68322-25P Cogent RP PFP™ HPLC Column has been a premium value trusted by HPLC laboratories for many years, delivering reliable performance and enhanced selectivity for complex separations. This column is fully double end‑capped and bonded via a four‑carbon linker to a benzene ring substituted with five fluorine atoms, using ultra‑high purity silica.
The column provides multiple retention mechanisms—including π‑π interactions, dipole interactions, and hydrogen bonding—making it highly effective for halogenated, aromatic, and polar analytes. It also serves as a suitable alternate column for USP methods where PFP selectivity is advantageous.
With a 3 µm particle size, this column offers higher efficiency than 5 µm columns of the same phase, delivering sharper peaks and improved resolution. As expected, the smaller particle size increases backpressure compared to larger particle columns.
250 mm Length – Maximum Resolution for the Most Demanding Separations
The 250 mm length provides the highest resolving power, making it ideal for complex mixtures and challenging separations.
Maximum resolution compared to shorter column lengths
Superior separation of closely related and co-eluting compounds
Increased peak capacity for complex samples
✅ Recommended for impurity profiling, method development, and highly complex analyses
Flow Rate & System Requirements (4.6 mm ID, 3 µm)
⚠️ Compatible with standard analytical HPLC systems, with higher backpressure due to column length and particle size
Typical flow rate range: ~0.8 – 1.5 mL/min
Higher efficiency than 5 µm columns
Increased backpressure from 3 µm particles and 250 mm length
Suitable for UV and standard analytical detectors
✅ Best Practice: Filter samples using a 0.2 µm syringe filter prior to injection
Why Choose PFP (F5) Columns for Selective Separations
Enhanced Retention for Halogenated Compounds
Strong interaction with halogenated and fluorinated analytes
Improved selectivity vs C18 columns
Multiple Interaction Mechanisms
π‑π interactions for aromatic compounds
Dipole and hydrogen bonding interactions
Greater flexibility for method development
Versatile 100 Å Pore Structure
Suitable for small to moderately sized molecules
Balanced performance across applications
Cogent RP PFP™ Column Advantages
Fully End‑Capped Surface
Minimizes silanol activity
Improves peak symmetry
High Efficiency (3 µm Particles)
More efficient than 5 µm columns
Sharper peaks and improved resolution
High Purity Silica
Consistent and reproducible chromatographic performance
Long column lifetime
Typical Applications
Halogenated compound analysis
Aromatic compound separations
Polar compound retention
Pharmaceutical QA/QC workflows
Method development and impurity profiling
USP alternate methods
Important Usage Notes
Packed and shipped in reversed‑phase solvents
Designed for standard analytical HPLC systems (4.6 mm ID)
Higher backpressure due to particle size and column length
Use 0.2 µm filtration prior to injection